Problem: The injection machine don't lock the mold while using 3-axis robot arm automatically

Reason 1: 3-axis robot arm turned off the switch of mold locking.
Solution: Open and close the safety door - one time.
Reason 2: 3-axis robot alarm.
Solution: Cancel the alarm, then open and close the safety door one time.
Reason 3: Circuit board has a problem (Recycling problem).
Solution: Replace the recycling appliance, or repaire the circuit board.
Reason 4: If set the 3-axis robot program to "robot standby outside of mold".
Solution: Set the 3-axis robot program to "robot standby inside mold" or "robot standby outside mold "according to your actual requirements. If set "robot standby outside mold", mold can only be locked after the robot arms moved outside of the mold.

Problem: 3-axis robot arm don't move down automatically

Reason1: Mold open complete signal has a problem.
Solution: Check if injection machine output the mold open complete signal.
Reason2: Full-automatic signal has a problem.
Solution: Check if open the function of "robot full automatic". normally, the automatic status should be " open".
Reason3: Safety door signal has a problem.
Solution: Check if the injection machine safety door signal is working.
Reason4: Wire connection between robot and injection machine has a problem.
Solution: Check if the wire connection is correct, or if the connection area is loose, or wires break.
Reason5: Injection machine didn't open the "robot function",or robot is set" not use". Aviation plug is not plug in "use robot".
Solution: Open the injection machine "robot function".